Power Quality Analyzer
Click image to enlarge -
Click image to enlarge
MODEL: MTP 3200

  • Input Channels: 4 (3 phase + neutral) DC coupliing
  • Measures: Voltage, AC Current, Frequency, Dips & Swells, Harmonics, Power and Energy, Flicker, Unbalance, Voltage Transient, Inrush Current
  • Max. Input Voltage: 1000Vrms
  • Current Range: varies according to clamp models, several optional clamps available (See Spec. sheet or user manual)
  • Sampling Resolution: 20000 samples / 8 channels, 16 bits AD
  • Integrated and external memory
  • Complies with IEC61010-1, 600V CAT IV / 1000V CAT III
 
 
Current Clamp-On Adaptor 50A
MODEL: MTP 3200-CTC0080

  • Optional Accessory for MTP 3200, Power Quality Analyzer
  • Measurement Range: 50A
  • Ouput Voltage Ratio: 10mV/A
  • Working Frequency: 50Hz - 400Hz
  • Accuracy: 0.2%
  • Clamp Radius: 8mm
  • Dimensions (mm): 171 x 46 x 27
Click image to enlarge -
Click image to enlarge
 
 
Current Clamp-On Adaptor 100A
Click image to enlarge -
Click image to enlarge
MODEL: MTP 3200-CTC0130

  • Optional Accessory for MTP 3200, Power Quality Analyzer
  • Measurement Range: 100A
  • Output Voltage Ratio: 10mV/A
  • Working Frequency: 50Hz - 400Hz
  • Accuracy: 0.2%
  • Clamp Radius: 13mm
  • Dimensions (mm): 174 x 52 x 27
 
 
Current Clamp-On Adaptor 1000A
MODEL: MTP 3200-CTC1535

  • Optional Accessory for MTP 3200, Power Quality Analyzer
  • Measurement Range: 1A - 1000A
  • Output Voltage Ratio: 1mV/A
  • Working Frequency: 40Hz - 100KHz
  • Accuracy: 1%
  • Safety: CAT III 600V
  • Clamp Radius: 52mm
  • Dimensions (mm): 111 x 216 x 45
Click image to enlarge -
Click image to enlarge
 
 
Current Clamp-On Adaptor 5A
Click image to enlarge -
Click image to enlarge
MODEL: MTP 3200-KLC8C-5A

  • Optional Accessory for MTP 3200, Power Quality Analyzer
  • Measurement Range: 5A
  • Output Voltage Ratio: 10mV/A
  • Working Frequency: 45Hz - 55Hz
  • Accuracy: 0.2%
  • Clamp Radius: 8mm
  • Dimensions (mm): 158 x 43 x 24
 
 
Flexible Current Clamp-On Adaptor 3000A
MODEL: MTP 3200-PY-3000A

  • Optional Accessory for MTP 3200, Power Quality Analyzer
  • Primary Current Rating: 3000A
  • Output Voltage Ratio: 65mV/1000A
  • Measurement Range: 15A - 3000A
  • Accuracy: +/-1% + Position Error
  • Maximum Allowable Input: 100KA
  • Phase Error: <+/-1 degree
  • Noise: <2mVrms (10Hz - 10KHz)
  • Frequency Characteristic: 10Hz - 10KHz (-3dB)
  • Weight: 130g - Length: 200cm
  • CT Perimeter: 50mm
  • Measurement Position Error: +/- 2%
Click image to enlarge -
Click image to enlarge
 
 
Flexible Current Clamp-On Adaptor 5000A
Click image to enlarge -
Click image to enlarge
MODEL: MTP 3200-PY-5000A

  • Optional Accessory for MTP 3200, Power Quality Analyzer
  • Primary Current Rating: 5000A
  • Output Voltage Ratio: 50mV/1000A
  • Measurement Range: 20A - 5000A
  • Accuracy: +/-1% + Position Error
  • Maximum Allowable Input: 100KA
  • Phase Error: <+/-1 degree
  • Noise: <2mVrms (10Hz - 10KHz)
  • Frequency Characteristic: 10Hz - 10KHz (-3dB)
  • Weight: 130g
  • Length: 200cm
  • CT Perimeter: 50mm
  • Measurement Position Error: +/- 2%
 
 
Power & Harmonics Analyzer
MODEL: Prova 6830A

  • Analysis for 1P2W, 1P3W, 3P3W, 3P4W
  • True RMS value (V 123 and I 123)
  • Active power (W, kW, MW, GW)
  • Apparent and reactive power (KVA, KVAR)
  • Power factor (PF), phase angle (Ø)
  • Energy (WH, KWH, KVARH, PFH)
  • Current measurement from 0.1 mA to 3000A, capable of analysing IT standby power measurement consumption to the maximum demand of a factory
  • Programmable CT (1 to 600) and PT (1 to 3000)
  • Display of overlapped voltage & current waveform
  • Average demand (AD in W, KW, MW)
  • Maximum demand (MD in KW, MW, KVA, MVA) with programmable period
  • Harmonic analysis to the 99th order
  • Displays waveform with peak values (1024 samples/period)
  • Analysis of total harmonic distortion (THD-F)
  • Graphic phasor diagram with 3 phase system parameters
  • Captures 28 transient events (time + cycles) with programmable threshold(%)
  • DIP, SWELL, and OUTAGE are included in transient events
  • 3 Phase voltage or current unbalanced ratio (VUR, IUR)
  • 3 Phase voltage or current unbalanced factor (d0%, d2%)
  • Analysis of total harmonic distortion (THD-F)
  • Calculated unbalanced current through neutral line (ln)
  • 512K memory with programmable interval (1 to 6000 seconds, 17000 records for 3P4W system)
  • Output of waveform, power parameters and harmonics at command
  • Built-in timer and calendar for data logging
  • Unit comes with one of the four options : x03 test clamps 100A (6801) OR x03 test clamps 1000A (6802) OR x03 flex clamps 3000A (3007) OR x03 flex clamps 1200A (3009)